Aaf-international Type W RotoClone User Manual

Browse online or download User Manual for Equipment Aaf-international Type W RotoClone. AAF International Type W RotoClone User Manual [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Type W RotoClone
®
Wet Centrifugal Collector
Installation, Operation,
and Maintenance Instructions
Better Air is Our Business
®
IMPORTANT:
Read this manual before installing or operating the equipment.
This manual should remain with the equipment for reference
regarding operation, maintenance and repair/parts. Write down
the information from the nameplate on the W RotoClone and
copy it to the front of this IOM for future reference.
Retain all drawings and documents that came with the RotoClone
(in the “Instructions Envelope”) and keep with the IOM in a readily
accessible location.
If you are an installer and not the owner of this equipment, all
of these documents should be submitted to the end user, upon
completion of the installation.
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - Type W RotoClone

Type W RotoClone®Wet Centrifugal CollectorInstallation, Operation, and Maintenance InstructionsBetter Air is Our Business®IMPORTANT: Read this manual

Page 2 - 1.0 Description

RotoClone Size C = Cap ScrewsF = ImpellerClearance8 3/8 - 16 X 1 5/16 - 7/1610 3/8 - 16 X 1 7/16 - 9/1612 3/4 - 10 X 1 9/16 - 11/1614 3/4 - 10 X 1 9/1

Page 3

115.0 Troubleshooting5.1 Water Entrainment - Excessive discharge of water in the exhaustmay be due to the following:• Incorrect rotation (correct rota

Page 4

12NOTE 1: Shipping weight does not include motor and drive.NOTE 2: Operating weight includes estimated weight for motor and drive for Arrangements “A”

Page 5

7.0 StorageTemporary (30 days or less) storage of W RotoClones should beindoors in a controlled atmosphere, free from dirt and moisture.Long term (gre

Page 6

14Type W RotoClone Parts List:1. Expansion Chamber Assembly2. Impeller Shaft 3. Bearing, Shown on4. Water Cone Assembly 5. Inlet Cone Assembly6. Impel

Page 7 - 4.0 Maintenance

9.0 Supplements For Optional Features9.1 Food Quality W RotoClones “Food Quality” refers to features on the W RotoClone that make it readily accessibl

Page 8

Type W RotoClone® 10300 Ormsby Park Place Suite 600Louisville, Kentucky 40223-6169www.aafintl.comCustomer Service 800.477.1214 Fax 800.254.3019AAF has

Page 9

Table of Contents1.0 Description2.0 Installation2.1 Foundations 2.2 RotoClone Erection (Arrangement A & D) 2.3 Duct Connections (Arrangement A &am

Page 10

2.0 InstallationThe following instructions should be read carefully before installing the RotoClone.2.1 Foundations Foundations must be true, level, a

Page 11 - 5.0 Troubleshooting

RotoClone Erection (Arrangement D) Refer to Arrangement D Erection Diagram - Figure 2. Assemblyshould proceed in the following manner, using gaskets a

Page 12

52.3 Duct Connections (Arrangement A) Inlet and discharge ducts must be supported from floor, wall, or ceiling, and not by the RotoClone. The joint be

Page 13 - 7.0 Storage

Figure 4 — Piping Diagram, Arrangements A and D2.6A Pressure Switch A switch is supplied with the RotoClone which will stop the RotoClonemotor automat

Page 14 - 8.0 Parts List

72.12 Drive Type W RotoClones are belt-driven. Motor, if supplied by others,should be equipped with adjustable slide base. Short center V-belt drive,

Page 15 - RotoClone Inlet

4.8 Shaft SealOther than routine greasing of the shaft seal (see 4.1 Lubrication), theshaft seal requires no maintenance. Should the seal fail, replac

Page 16

94.9 Replacement of Shaft, Impeller or Water Cone Removal of the shaft, impeller, or water cone requires access to the front of the scroll. This is mo

Comments to this Manuals